| SI AUTO Bench top |
SI AUTO work station |
| Features |
Three wash programmes |
Three wash and Three disinfect programmes |
Wash time and temperature two line LCD Display |
Wash time and temperature two line LCD Display |
Automatic Hot and Cold fill |
Automatic Hot and Cold fill |
Lid interlock system to prevent Ultra-Sonics running with the lid open |
Lid interlock system to prevent Ultra-Sonics running with the lid open |
Automatic wash detergent dosing |
Automatic wash detergent dosing |
Automatic final stage chemical dosing |
Automatic final stage chemical dosing |
18 load carrier flush outputs |
18 load carrier flush outputs |
Control Fascia is wipe clean polycarbonate |
Control Fascia is wipe clean polycarbonate |
Stainless steel lid with gas spring assistance |
Stainless steel lid with gas spring assistance |
Twin temperature sensors, self checks for errors |
Twin temperature sensors, self checks for errors |
APG XP Sonic generator 8 horn transducers |
APG XP Sonic generator 8 horn transducers |
Low water level protection to prevent heater and Ultra-Sonics from being activated with low or no water. Programme aborts |
Low water level protection to prevent heater and Ultra-Sonics from being activated with low or no water. Programme aborts |
CPE Pump technology (Six pumps) |
CPE Pump technology (Six pumps) |
Pressure limited to 1.5 bar |
Pressure limited to 1.5 bar |
Drain. Automatic draining as part of the process |
Drain. Automatic draining as part of the process |
| Fused L & N, Fused Ultra-sonic generator and control PCB |
Fused L & N, Fused Ultra-sonic generator and control PCB |
| High Grade corrosion resistant stainless steel with brushed finish (316) |
High Grade corrosion resistant stainless steel with brushed finish (316) |
Printer output for process monitoring (RS232) 9 pin D (8 bit no parity 2400 baud)
Machine ID
Cycle number,
Date & time
Wash time
Wash temperature
|
Printer output for process monitoring (RS232) 9 pin D (8 bit no parity 2400 baud)
Machine ID
Cycle number,
Date & time
Wash time
Wash temperature
|
| At a glance stage indicator LEDs |
At a glance stage indicator LEDs |
| Final stage is air purge to remove water from internal parts |
Final stage is air purge to remove water from internal parts |
| Bench top required |
Supplied with floor standing cabinet housing thermal booster |
| |
Separate hot water storage heater housed in cabinet for wash and disinfect. (Thermal Booster) |
| |
Idle temperature of 75°C when the main unit is switched off. Normal temperature of 90°C when in use |
| Typical Programmes |
|
P1 |
P2 |
P3 |
P4 |
P5 |
P6 |
Spray Rinse Min |
2 |
2 |
2 |
2 |
2 |
2 |
Pre Wash time Min |
3 |
3 |
3 |
3 |
3 |
3 |
Wash Time min |
5 |
10 |
20 |
5 |
10 |
20 |
Wash Temperature °C |
43 |
43 |
43 |
43 |
43 |
43 |
Detergent dose time sec’s |
12 |
12 |
12 |
12 |
12 |
12 |
Pre-Rinse time Min |
2 |
2 |
2 |
2 |
2 |
2 |
Pre heat Sec’s |
- |
- |
- |
30 |
30 |
30 |
Final cold rinse Min |
2 |
2 |
2 |
- |
- |
- |
Lubricant dose time Sec’s |
12 |
12 |
12 |
- |
- |
- |
Disinfect time Min |
- |
- |
- |
2 |
2 |
2 |
Disinfect temperature °C |
- |
- |
- |
80-85 |
80-85 |
80-85 |
Air purge sec’s |
120 |
120 |
120 |
120 |
120 |
120 |
The above programme parameters can be modified within limits to suit customer’s requirements. (Option)
Specifications
Quality
Manufactured in the UK under Medisafe’s IS09001 Quality
Use
For Internal and external cleaning of Fine Surgical Instrumentation, other lumen instruments.
Environmental
For indoor use at altitudes up to 2000m.
Operating temperature -5°C to 40°C.
Humidity -80% RH max for temperatures up to 31°C,
decreasing linearly to 50% RH at 40°C.
Designed for Pollution Degree 2, i.e. not totally sealed.
General
Description
Medical Device Class I to class IIa
Intended Purpose
Internal and external cleaning of surgical instruments, hollow-ware, and associated products
Operating Process
Ultrasonic activity plus CPE
Applied Standards
BS2745: part 1: 1993
BS2745: part 3: 1993
EN60101-1:2001 (2nd Edition)
EN61010-2-045 (2001)
EN61326: 1997
A1: 1998
EN980
Wash Cycle Parameters
Min. Temp. During Cycle: determined by temperature of water supply
Max. Temp. During Cycle: 90° C.
Vol. of Dispensed Chemicals
Wash chemical: Detergent 160ml (approx)
Final rinse chemical: 160ml (approx)
Required Services
Electricity Supply
Main Unit:
Supply Voltage: single phase 230v 5 amps (nominal) AC
Supply Frequency: 50 Hz
Power Consumption: 0.8KVA max.
Termination: 3 pin type earthed plug (UK fused @ 13A)
Lead Length: 1.83M (6 feet)
Thermal Booster:
Supply Voltage: single phase 230v 13 amp (nominal) AC only
Supply Frequency: 50 Hz
Power Consumption: 3KVA max.
Termination: 3 pin type earthed plug (UK fused @ 13A) **
Lead Length: 1.83M (6 feet)
Printer:
Supply Voltage: single phase 230v 0.1 amps (nominal) AC
Total of three sockets.
(** termination MUST be to a permanently live and earthed switched & fused outlet)
Water Supply COLD
Main Unit:
Volume Used per Cycle: MAX. 75 litres
Acceptable Temp. Range: 15 - 25° C.
Supply Connection: ¾” BSP Male Union
Optimum pressure: 1.5 BAR (22 psi)
Acceptable Pressure Range: 1 – 2 BAR (15 – 30 psi)
Acceptable Flow Rate: not less than 20 litres/min
Hardness: CaCo3 not more than 115ppm
Water Supply HOT
Bench top washer:
Volume Used per Cycle: MAX. 40 litres
Acceptable Temp. Range: 55- 80° C.
Supply Connection: ¾” BSP Male Union
Optimum pressure: 1.5 BAR (22 psi)
Acceptable Pressure Range: 1 – 2 BAR (15 – 30 psi)
Acceptable Flow Rate: not less than 20 litres/min
Hardness: CaCo3 not more than 115ppm
Thermal Booster:
Volume Used per Cycle: MAX. 40 litres
Acceptable Temp. Range: 50 - 80° C.
Supply Connection: ¾” BSP Male Union
Optimum pressure: 1.5 BAR (22 psi)
Acceptable Pressure Range: 1 – 2 BAR (15 – 30 psi)
Acceptable Flow Rate: not less than 20 litres/min
Hardness: CaCo3 not more than 115ppm
Drain
Main Unit:
Discharge Orifice Type: 18mm outside dia. unthreaded hose tail
Position of drain: at least 150mm below rear drain outlet
Max. Flow to Drain: 20 litres/min
Max. Temp. of Effluent: 95° C.
Overflow / vent
Thermal Booster:
Overflow Orifice Type: 22mm outside dia. stainless steel tube
Position of drain: at least 150mm below overflow outlet
Max. Flow to Drain: 20 litres/min (in overflow situation only)
Max. Temp. of Effluent: 96° C.
Ventilation
Max. Heat Output of Load: 95° C.
Weight & Dimensions
Bench Top
Operational weight
40.5kgs
Dimension:
Wash Chamber Volume: 27,000 cm3
Outer Cabinet Dimensions:
928 mm (w)
445 mm (d)
376 mm (h)
Workstation
Operational weight:
100kgs
Dimensions
Wash Chamber Volume: 27,000 cm3
Outer Cabinet Dimensions:
928 mm (w)
445 mm (d)
1050 mm (h)
|